PT-10
10mm carbon through-hole potentiometer
The PT-10 potentiometer offers control where frequent adjustment is required. The shaftless design allows for employment of different engagement mechanisms, such as a customized shaft, a motor control or a human interface adjustment. This potentiometer can also control variable outputs including frequency, change in motor speed or volume.
■ Excellent performance (up to 3% linearity)
■ Up to 16 mechanical detents for tactile feedback
■ Up to 100.000 life cycles
■ IP54 protection
■ Bulk, magazine or embossed tape (reel) packaging
■ Polyester / Alumina substrate
■ Wiper positioned at initial, 50% or fully clockwise
■ Loose and assembled shaft and knobs
■ Linear, logarithmic and antilogarithmic tapers
■ Self extinguishable plastic (UL 94V-0) available
■ SPDT switch and low torque versions available
SPECIFICATIONS
Taper¹ | Lin, Log, Alog |
Range of values¹ |
(Decad. 1.0 - 2.0 - 2.2 - 2.5 - 4.7 - 5.0) Lin - 100Ω ≤ Rn ≤ 5MΩ Log, Alog - 1KΩ ≤ Rn ≤ 5MΩ |
Tolerance¹ |
± 20% - 100Ω ≤ Rn ≤ 1MΩ ± 30% - 1MΩ < Rn ≤ 5MΩ |
Max. Voltage |
Lin - 200 VDC Log, Alog - 100 VDC |
Nominal power |
50°C (122°F) Lin - 0.15 W Log, Alog - 0.07 W |
Residual resistance¹ | ≤ 0.5% Rn (5Ω min.) |
Equivalent noise resistance | ≤ 3% Rn (3Ω min.) |
Operating temperature |
-25°C to +70°C ² (-13°F to + 158°F) |
1 Others available on request; 2 Up to 85°C depending on application
Mechanical rotation angle¹ | 235° ± 5° |
Electrical rotation angle¹ | 220° ± 20° |
Torque |
Rotational - 0.4 to 2 Ncm (0.6 to 2.7 in-oz) Stop - > 5 Ncm (>7 in-oz) |
Push-pull force over the rotor | > 49N |
Life² | Up to 100k cycles |
1 Endless rotation available: ST-10; 2 Others check availability
Test method (CEI 393-1) | PT-10 %-% ΔR(%)- Piher typical test results | |
---|---|---|
Electrical life |
1.000h at 50°C; 0.15W 1.000h at 70°C; 0.33W |
±5% n/a |
Mechanical life | 1000 cycles at 10 to 15 cpm | ±3 % (Rn < 1M ) |
Temperature coefficient |
–25°C; +70°C -40°C; +90°C |
±300 ppm/°C (Rn < 100K)
n/a |
Thermal cycling |
16h at 85°C and 2h at -25°C 16h at 90°C and 2h at -40°C |
±2.5% n/a |
Damp heat | 500h at 40°C and 95% relative humidity (RH) | ±5% |
Vibration | 2h each plane at 10Hz - 55Hz | ±2% |
Storage | 6 month at 23°C ±2°C and 50% RH | ±2.5% |
Out of range values may not comply with these results. Standard test conditions: temperature:23°C ±2°C and 45% to 70% RH