PSC-15
15-mm cermet SMD potentiometer
The PSC-15 cermet potentiometers offer control where frequent adjustment is required. The shaftless design allows for employment of different engagement mechanisms, such as a customized shaft, a motor control or a human interface adjustment.
■ Excellent performance (up to 3% linearity)
■ Cermet resistive element
■ Up to 38 mechanical detents for tactile feedback
■ IP54 protection
■ Embossed tape packaging according to IEC 60286-3:2007
■ Wiper positioned at initial, 50% or fully clockwise
■ Linear, logarithmic and antilogarithmic tapers (PSC-15)
■ Self extinguishable plastic (UL 94V-0)
■ Locating pins for accurate PCB positioning
■ Low torque version available
■ Shaft and knobs
■ Controlled linearity up to 3% on request
SPECIFICATIONS
Taper¹ | Lin, Log, Alog |
Range of values¹ |
Lin - 100Ω ≤ Rn ≤ 5MΩ Log, Alog - 1KΩ ≤ Rn ≤ 5MΩ |
Tolerance¹ |
100Ω ≤ Rn ≤ 1MΩ - ± 20% 1MΩ < Rn ≤ 5MΩ - ± 30% |
Max. Voltage |
Lin - 250 Vdc Log, Alog - 125 Vdc |
Nominal power |
70°C (158°F) Lin - 0.50 W Log, Alog - 0.25 W |
Residual resistance¹ | ≤ 0.5% Rn (5Ω min.) |
Equivalent noise resistance | ≤ 3% Rn (3Ω min.) |
Operating temperature1 |
-40°C to +90°C (-40°F to +194°F) |
1 Others available on request
Mechanical rotation angle¹ | 265° ± 5° |
Electrical rotation angle² | 240° ± 20° |
Torque |
Rotational - 0.5 to 2.5 Ncm (0.7 to 3.4 in-oz) Stop > 10 Ncm (>14 in-oz) |
Life² | Up to 10k cycles |
1 Endless rotation available: STS-15 2 Others check availability
Test method (CEI 393-1) | ΔR(%) - typical test results | |
---|---|---|
Electrical life |
1.000h at 50°C; 0.15W 1.000h at 70°C; 0.33W |
n/a ±5% |
Mechanical life | 1000 cycles at 10 to 15 cpm | ±3% (Rn < 1 M) |
Temperature coefficient |
-40°C; +90°C -40°C; +85°C -25°C; +70°C |
±100 ppm/°C (Rn < 100K) n/a n/a |
Thermal cycling | 16h at 90°C and 2h at -40°C | ±2.5% |
Damp heat | 500h at 40°C and 95% relative humidity (RH) | ±5% |
Vibration | 2h each plane at 10Hz - 55Hz | ±2% |
Storage | 6 month at 23°C ±2°C and 50% RH | ±5% |
Out of range values may not comply with these results. Standard test conditions: temperature:23°C ±2°C and 45% to 70% RH