This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.
ST-15
15-mm carbon endless rotation through-hole potentiometer
360º rotary control (CW or CCW) with highly configurable mechanical and electrical specifications such as a wide variety of off-the-shelf mounting methods, custom ohmic (resistance) values, tight linearity performance, different rotor designs, shafts and knobs and built-in stop positions.
■ 360º mechanical rotation angle
■ Up to 340º electrical rotation angle
■ Up to 51 mechanical detents
■ Up to 200.000 life cycles
■ IP54 protection
■ Selection of shaft & knobs
■ Flame-retardant plastic materials
■ Custom electrical angles on request
■ SMD mount version: STS-15
SPECIFICATIONS
Taper | Linear |
Range of values* (Decad. 1.0 - 2.0 - 2.2 - 2.5 - 4.7 - 5.0) | 1KΩ ≤ Rn ≤ 100KΩ |
Tolerance* | ±30% |
Max. Voltage | 50 VDC |
Nominal power 50°C (122°F) | 0.25 W |
Residual resistance | ≤ 5% Rn |
Equivalent noise resistance | ≤ 3% Rn |
Operating temperature ** | -25°C to +70°C (-13°F to + 158°F) |
* Others available on request ** Up to 85°C depending on application
Mechanical rotation angle | Endless (360º) |
Electrical rotation angle* | 333° ±15º |
Torque |
Standard: 0.5 to 2.5 Ncm Low: ≤ 1.5 Ncm |
Life* |
Standard - 1.000 cycles Long - 10.000 cycles |
* Others available on request
Test method (CEI 393-1) | ΔR(%) - Piher typical test results | |
---|---|---|
Electrical life | 1.000h at 50°C; 0.15W | ±5% |
Mechanical life | 1000 cycles at 10 to 15 cpm | ±3 % (Rn < 1M ) |
Temperature coefficient | –25°C; +70°C | ±300 ppm/°C (Rn < 100K) |
Thermal cycling | 16h at 85°C and 2h at -25°C | ±2.5% |
Damp heat | 500h at 40°C and 95% relative humidity (RH) | ±5% |
Vibration | 2h each plane at 10Hz - 55Hz | ±2% |
Storage | 6 month at 23°C ±2°C and 50% RH | ±2.5% |
Out of range values may not comply with these results. Standard test conditions: temperature:23°C ±2°C and 45% to 70% RH
APPLICATION EXAMPLES